0%

    SH.18G03-MO-4000
    MO-4000 Water treatment system

    • Назначение
    • Технические характеристики

    The MO-4000 water treatment system is designed for water purification of open reservoirs and wells from suspensions, colloids, bacteria and viruses, including combat spore forms of biological agents, neutralization of highly toxic organic and inorganic matters, including combat toxic agents, deactivation of radioactive substances, removal of the compounds of iron, manganese, copper, sulfur, phosphorus, organic matters, including oil products, and dissolved salts, including the compounds of univalent, bivalent and polyvalent metals as well as for storage and delivery of the purified water under pressure to the consumer's main.

    The nominal throughput capacity of the system is 4.2 m3/h (100 m3/day), which is sufficient to provide:

    • 400 people according to the consumption rate established for urban people (250 l/person in day); 

    • 1,250 people according to the consumption rate established for the military personnel of the APL-500 autonomous field camp (80 l/person in day); 

    • 20,000 people when using water only for drinking and culinary.

     Advantages: 

    • The setup time of the MO-4000 is 2 h.

    •  The delivered system is fully ready for operation. 

    • It has the consumable, the set of instruments and the spare parts. 

    • The system consists of four blocks being in the common housing: the block for storage of source water, the block of water treatment, the block for storage of the purified water, the block for delivery of the purified water in the consumer's main.

    • When using the system, a pumping facility is not required.


    Dimensions of the system, mm, no more than

    1,000 (L) x 600 (W) x 1,800 (H)

    Average productivity of purified water (at +8°C temperature of source water), l/h, no less than

    400

    Peak consumption of purified water, m3/h, no less than

    2.0

    Pressure of purified water at the output of the system, MPa, no less than

    0.2

    Dry weight of the system, kg, no more than

    210

    Power supply

    220 V

    Power consumption, kW, no more than

    1.85

    Consumption of drainage water, m3/h, no more than

    0.4

    Pressure of drainage water at the output of the system, MPa

    0…0.05

    Pressure of source water at the input of the system, MPa,

    no more than

    0.4

    Permissible loads for the system housing

    up to 10 g at a frequency up to 1 Hz

    Ambient temperature for storage and operation, 0С

    +5…+40

    Service life prior to overhaul, m3 of purified water,

    no less than

    2,000

    Assigned resource, m3 of purified water, no less than

    12,000

    Manufacturer

    POLYUS Research Institute JSC


    Parameters of water purification

    Parameter, units

    Source water

    Purified water

    Drinking water according to Sanitary rules/norms

     2.1.4.1074-01

    Chromaticity, degrees

    50

    0

    5

    Smell, points

    5

    0

    1

    Taste, points

    5

    0

    1

    Turbidity by kaolin, mg/l

    200

    0

    0.5

    Total iron, mg/l

    11.5

    0.1

    0.3

    Manganese, mg/l

    0.5

    0.05

    0.05

    Sulfides, mg/l

    0.1

    0

    0.003

    Biochemical oxygen demand, mgO2/l

    10

    0.5

    2

    Ammonium, mg/l

    1

    0.03

    0.05

    Total hardness, mg-equivalent/l

    20

    1.5

    7

    Total mineralization, mg/l

    6,000

    300

    1,000

    Nitrates, mg/l

    200

    0.8

    5

    Chlorides, mg/l

    1,500

    100

    150

    Sulfates, mg/l

    2,800

    100

    150

    Phosphates, mg/l

    10

    0.5

    3.5

    Strontium, mg/l

    40

    4

    7

    Microbiological indices:

    a) bacteria  (forming and non-forming spores), m.t./l

    b) viruses, plaque-forming unit/l

    1·106

    1·106

    0

    0

    -

    -